It also secures the "gasket disk" in place for a perfect seal around the generator's filler neck everytime. Please click on the Product Details tab just below the photos for full technical details. While camping on the beach in the Texas Summer it can get very hot, and getting up at 3 or 4 am to fill the generator just so you could get some AC was tough but you would do it. . Firman 3200, 3300 & 3650 Extended Run Time Fuel Kit. With this system you can utilize a can tank that you currently own. External fuel tank with a three-way valve. I can't get any fuel to siphon out of the aux tank. Probably would need a check-valve (back flow preventer) between the internal tank and quick-connect to prevent gas from flowing from the external tank to the internal tank. The fuel line can easily be shortened if desired. This is a great way to save money and extend the life of your generator. Consulting the owners manual for the manufacturers recommendations. The vacuum draw technology ensures a seamless flow of fuel from the BERG System to the generator. Both are running and are siphoning gas up to the generators. A note about the hose leading out of the gas tank: you can buy hose of pretty much any length you want. Do you plan on using your B.E.R.G. Things go Boom all the time because someone takes a shortcut. Our Extended Run Time Fuel Kits are the safest and most convenient way to extend the run time of your generator. You first fill the Honda 2000 tank then attach the fuel line from your 6 gallon marine tank. IPI Industries Breeze Extended Run Generator System BERG System: Dual Feed, Model# HND1.2-000iD. B.E.R.G. This setup should do nicely. Extended Run Generator System (amzn) The key component for a system like this is the cap leading to the internal tank, this one with a hose barb: Extended Run Fuel Gas Cap (amzn) This particular one does not have a quick disconnect feature but given the cap screws on and off quickly, it may not be necessary. Then repeat this process with the other end of the hose and the other hole in the top of the container. Use your system daily or yearly and the fuel will flow seamlessly from the B.E.R.G. In theory, the gas leaving the tank on the generator creates a vacuum and pulls the fuel from the extended run tank when it is above the generator tank. For this you need a hose splicer such as this:3 Way Union Fitting. IPI Industries Breeze Extended Run Generator System BERG System: Single Feed, Model# HND1.2-000iS Item # 213800 Capacity: 6 Gal Fuel Type: Gasoline Extended Run Time: 72 hr $149.99 Shipping: Available now See Shipping Options Store Pickup: Not Available Check stores Add to Cart Compare Save to List Top Seller This will usually involve welding in a new tank, which can be done by a professional or someone with experience. Another problem was you had to let the generator cool down before refueling, and even then there was spilled gas and the potential for explosion. The ingenious MERGS system solves the problem with an elegantly simple fool-proof design that employs robust military & marine grade components, all ready to use right of the box. To use it, simply pour fuel into the container and then connect one end of the hose to your generators fuel intake port. To this one would attach something that looks like this female adapter barbed fitting:Brass Hose Barb Fitting, Female Adapter. $149. IPI BERGS 2 Dual Generator Extended Run Fuel System (Tank included) Part # HND1.2000ID The fuel line and stock Honda mower gas cap was bought at a local Honda and mower shop. HND1.2CD Dual System Extended Run Generator Fuel Kit for Honda EU1000i, EU2000i, EU2200i, Polaris P1000i, Champion 2000, Generac and Kipor Generators ( Without Fuel Tank) . My fuel dont go bad. Shop our extended run fuel systems for generators with patented technology. This item has not been validated to work with propane or dual fuel generators. If the Honda generator does not draw fuel from the remote tank without the remote tank being elevated there is probably an air leak. From an application standpoint, No. You should easily hear the air whooshing out of the vent pipe inside the tank. The principle is the same though: just depress some sort of a lever and pull the fitting apart! I've heard Honda recommends against the use of the external tank . Fully drain and disconnect internal tank, and connect remote tank directly to intake hose to the carburetor. We use cookies to analyze website traffic and optimize your website experience. Taa daa! I ask Ken if he would be good enough to post a link. One problem was limited fuel reservoir in the generator. BERG III was designed for larger size generators and pumps. Factory tanks are above on most and they rely on gravity feed. Complete system includes tank, hose, fittings, air line, and gas cap. Register (free) for Login credentials. This system is designed to run one generator. MADE IN THE U.S.A.with aLIFETIME WARRANTY! IPI Industries Midwest will never sacrifice performance, safety, or quality for profits. There are two basic kinds of fittings: hose barb and quick connect. Ill try and remember to go back cut n paste into it then. Drill a hole in each piece big enough to thread a hose through (the hose should be slightly wider than the fuel line on your generator). TheB.E.R.G. If this is the case, you can easily make an extended fuel tank for your generator using a few simple supplies. It is very important that you use only the components supplied in the kit, do not mix and match with locally improvised items due to the fact that they may not be 100% compatible and therefore inhibit performance of the kit. The plan is to carry our inflatable dinghy in the back of our Dakota along with the outboard but dont want to carry fuel in the passenger compartment. This is the full-up briefing, which includes information about MERGS background, test, evaluation, development and component specifics. This tank can hold up to 250 gallons of fuel, which is enough to keep most generators running for days or even weeks at a time. So, I would check that the fuel cap on the Honda is the correct non-vented type, the gaskets for that cap is intact, the quick change fittings are proper . I system will outlast yourgenerator, that they back it with aLIFETIME WARRANTY! Its's got a 5gal capacity and includes a shut off valve. . Thank you. Customer reviews and photos may be available to help you make the right purchase decision! . This option involves tapping into the line between your internal tank and the carburetor, and making it possible to continue to use the internal tank but also attach a quick connect-equipped boat tank. FAQ | CONTACT US | TERMS & AGREEMENTS | TIP JAR making sure the barb size matches your carburetor intake hose. B.E.R.G. Once established, it should keep going by siphon. If you have one of these generators but you are not comfortable installing the kit yourself, contact me for assistance. I have been using a 6 gallon tank with my 2800 watt Yammie back at the fishing camp for years. Fits all Champion 4500 and 4650 Inverter Generators Machined in the USA from 6061 Solid Billet Aluminum The high grade fuel line is impervious to gasoline & ethanol. Quick view . Requires a 12-Volt, Group 31, 925 CCA Battery available at local retailers. . Measure and mark where you will cut the halves apart, Drill two holes in each half of the fuel tank, about an inch from the edge that you just cut, Insert two bolts into each hole, and screw them in until they are tight, Place the halves of the fuel tank back together, lining up the holes that you just drilled, Screw in four more bolts around the perimeter of the fuel tank to hold it together tightly, 8 Fill the extended generator fuel tank with gasoline, using a funnel if necessary to avoid spillage. IPI is so confident that your B.E.R.G. In this case get a variant that steps down the hose size or is a reducer fitting. Eelpoutguy Participant Farmington, Outing Posts: 8144 December 5, 2015 at 3:50 pm #1582304 Elegantly simple gravity-feed system. Northern Tool's Powerhorse 2000 generator is compatible with MERGS (but the newer 2300i model is not compatible yet). Copyright 2022 Morgan Extended Run Generator System - All Rights Reserved. I've sold all my F550's and C5500's they were gasoline powered machines so yes the machines were tapped into the trucks fuel tank. Be aware that these generators are not rated for continuous service. Sam's Club & Amazon distributes the SUA 2300i generator, which is compatible with MERGS. Bobby G, Extended Run Generator Fuel System with 6 Gallon Fuel Tank - IPI Industries BERG System,YMH1.2000IS, 1 - Aircraft grade fuel lines with precision fittings. You first fill the Honda 2000 tank then attach the fuel line from your 6 gallon marine tank. As an Amazon Associate, I earn from qualifying purchases. 1983 - 2012 Ranger & B-Series Escape & Escape Hybrid Aerostar Crossovers Older, Classic & Antique Trucks 1987 - 1996 F150 & Larger F-Series Trucks 1980 - 1986 Bullnose F100, F150 & Larger F-Series Trucks 1973 - 1979 F-100 & Larger F-Series Trucks 1967 - 1972 F-100 & Larger F-Series Trucks 1961 - 1966 F-100 & Larger F-Series Trucks Both do exactly what is advertised. The system works by vacuum, drawing fuel from the marine tank into the Honda tank . BERGS I Gravity Feed is designed to work with generators that do not have a built in fuel pump. The fuel sock above and a filter placed below is too much restriction. I've got a Yamaha, without the pump and the external tank does not work with mine. The quick connect isas its name suggests. By accepting our use of cookies, your data will be aggregated with all other user data. How does it shut off the fuel at the tank? WEN inverter/generators models 56200i and 56225i are compatible with MERGS and are available on Amazon. Timing on this is great as we are looking for a small generator to mount on the rear bumper of our travel trailer. IPI BERGS 2 Dual Generator Extended Run Fuel System (Tank included) Part # HND1.2000ID, IPI BERGS 1 Extended Run Fuel System (Tank not included) Part # GHND1.2CS, IPI BERGS 1 Extended Run Fuel System (Tank included) Part # HND1.7000IS, Honda / Generac - Gasket Replacement Set (5) Pack - IPI-73257, Extended Run Generator Fuel System with 6 Gallon Fuel Tank - IPI Industries BERG System,YMH1.2000IS, IPI BERGS 1 Extended Run Fuel System (Tank not included) Part # HND1.7CS, IPI BERGS 1 CAP (works with honda 2000 and many more replacement cap only), IPI BERGS Single to Dual Conversion Kit (Tank not included Part# GHND1.2SD-K, IPI BERGS 1 Extended Run Fuel System (with tank) Part # RYB1.2200S, IPI BERGS 1 Extended Run Fuel System (Tank Included) Part# BS.P2200.S, IPI BERGS 1 Extended Run Fuel System (Tank Not Included) Part # HND1.3200iCS, Honda EU3200i-1 Cap (Cap Only includes gasket), IPI BERGS 1 Extended Run Fuel System (Tank included) Part # HND3.2000iS, IPI BERGS 1 Cap for Firman Generator 2000, IPI BERGS 1 Extended Run Fuel System (Tank Not Included) Part #FRMN1.2CS, IPI BERGS 1 Extended Run Fuel System (Tank Included) Part #, Yamaha 2200iS Dual System (Tank not Included), IPI BERGS Extended Run Fuel System for Honda EB2800i (Tank Not Included), IPI BERGS I Extended Run Fuel System for Honda EB2800i (Tank Included). This kit includes everything needed except the fuel tank itself, kits contain additional items not shown in photo. MADE IN THE U.S.A.with aLIFETIME WARRANTY! Lastly, why ohhhh why did you have to mention a Boat Fuel Tank, I have a particular aversion to ANYTHING to do with Boats.. 5 total Boating accidents involving the loss of firearms and ammo, so NOT happy with Boats. The situation cleared up when I downsized the hose to a smaller volume. Login to post a comment. This is a less common method, but it can be done if youre experienced with working on cars. IPI Industries relied on its years of experience in the aerospace and defense industries to select the finest inAMERICANandGERMANengineered couplers. With the gravity feed systems the external gas tank has to be elevated above the generator in order for the system to function. If you see any spelling errors, typos, non working links, or other issues, please let me know. For a simple hose barb connector, consider something that looks like this:Barbed Straight Connector Brass Fittings. The electrical generation portion, I really dont know how it stands up to long term running. A nice pit bike. B.E.R.G.S III The Canadian military replaced their old metal jerry cans with these high quality HDPE containers, which are fully compliant with the Portable Fuel Container Safety Act of 2020. Generator manufacturers advertise a burn rate of approximately 1 pint per hour when the generator is under a constant 25% load. Possibly an idea for the Project Farm guy on YouTube. There is someone on ebay that sells extended run fuel adapters for the small honda generators, it works by converting the regular honda vent on/off style fuel cap with a hose adapter that feeds from a portable boat engine style fuel tank. We do our best to select the highest quality components for our kits, for example we tested several different brands of prime ball hose before we chose the Yamaha hose due to the fact that it outlast the other brands and it stays more flexible in cold temperatures. Then Hurricanes Francis and Jeanne hit in Florida in the early to mid-2000s. How to Make Extended Fuel Tank for Generator? Is it mechanical with a cable, or electrical? The fittings are all the same. ava_marie78. Very convenient to use and very nice fishing for days with out having to refuel. The gravity feed needs the flow, post **** , to be un interrupted. ( yeah me too, if you cant figure it out, get the owners manual ) Amazon sells the Pulsar G2319N generator, which is compatible with MERGS. He asked me about fuel usage and if it is possible to attach an extra fuel tank to extend the run time. Support MSB(no xtra cost to you)enter AMZN here MSB Portal. 4. !; the rubber gaskets are NOT made to be compatible with fuel. Just a thought, for those for whom weight is an issue. To what extent should I be concerned? I tested the system today. This extended run generator system extends the run time of a suitcase style generator. For quick connect style youll need to mate your quick connect female fitting on the tank to a compatible male fitting on the motor. Those generators have a fuel pump much like the pump used on . I ran two generators off one 6.5 gallon tank. Under heavy load, or in general usage? Firman 3200, 3300 & 3650 Extended Run Time Fuel Kit. You will never have to risk personal injury again pouring gasoline into a hot generator. 3. Products for Boliy Pro3600Si & Pro3600SiE. Wow Bogan, good idea. Princess Auto in Canada is one of my customers; in turn they treat their customers very well indeed. I learned this the hard way when rigging a boat with a gas tank way in the front and used a long hose. Kit includes a yellow pour spout which can be used to empty the MERGS tank into another fuel tank, so no need to run the MERGS tank dry for storage. This means is you get anOVER ENGINEEREDproduct that will last a lifetime. I extended run generator fuel system provides a reliable connection between an external fuel tank and a generator extending the run time of the generator. Our Firman Extended Run Time Fuel kit is designed to alternate from one tank to the next while the generator is still running. Now you can just switch from one remote fuel tank to the next more safely at a distance of up to 10 feet from your generator. (gravity fed) View All; Ryobi Ryobi 2200; Ryobi 2300 Bluetooth; . I like this idea of an external fuel tank. Took a little over 2 hours to install the first kit and a little less than 2 hours to install the second kit. BTW if your in-line hose is inch, then the 6mm fitting is your huckleberry. Secondly, think about the size how much extra capacity do you need? Our kits are designed to alternate from one tank to the next while the generator is still running. EXTENDED RUN FUEL CAP WITH VITON SEAL, 1/4" BRASS ELBOW, CHROME PLATED BRASS QUICK DISCONNECT WITH MALE ADAPTER, INLINE FUEL PRIMER BULB WITH CLEARVIEW FUEL FILTER AND CLEANABLE ELEMENT, B1-15 EPA LOW . For safety reasons place generator and fuel tank on level ground when using and make sure fuel tank and hose are not near any heat source or open flame. Product specifications subject to change without notice. 5) Wrap this entire assembly in heavy-duty aluminum foil, making sure that there are no gaps or holes. Our kits use an internal fuel pump to transfer fuel so the remote tank does not need to be higher than the generator to work correctly. If you have an in-line fuel shut off, just put your Tee for the QD below the fuel line shut off valve. With the BERGS tank and the generator tank both full, mine will run for over 72 hrs. Maybe intermittent, the worst sort of problem to resolve. #6. I have a question about extended use of small portable generators. There are a few different ways that extended fuel tanks can be attached to generators. It says 6 but I couldnt stand it anymore so I used it lol. WORKS WITH Yamaha 1000/2200I, Powerhorse 2000 (gravity fed). Enter boat fuel tanks! This particular one does not have a quick disconnect feature but given the cap screws on and off quickly, it may not be necessary. There is no priming or pumping needed. This 2.2 gallon tank attaches to the side of the generator and doubles the amount of fuel that you can carry with you. A clean plastic drum or gas can works well for this purpose. Paul said he had not heard of the Firman series generator and asked if I could send he some pictures. The heart and soul of IPIs BERG System, this patent pending precision machined cap is engineered from pure aircraft grade 6061 aluminum. If we are out of stock on the unit you are looking for please send us an email and we can get it ordered. This system is designed to run one generator. Next, drill two holes in the top of the container, one near each end. 2 fuel oil can operate on diesel without any issues. IPI is so confident that your B.E.R.G. This Kit works with Firman 3200, 3300, and 3650 inverter generators. If youre looking to increase the size of your gas tank, there are a few different ways you can go about it. I extended run generator fuel system allows you to supplement your generator's factory fuel capacity with a stable vacuum powered fuel supply. I system to your generator. OTOH, if you ever have a question or issue with that gennie, perhaps something others in the forum could benefit from (and if its ok with Ken, of course), post it in the weekend free-for-all and maybe others will benefit from the exchange. 6) Connect one end of the hose to the filler neck on your generator and route it through both pieces of wood or metal before connecting it to the extended fuel tank. Your review*document.getElementById("comment").setAttribute( "id", "a90ece2f8371f83fbe7f7435d1fbab8c" );document.getElementById("ee54d7797e").setAttribute( "id", "comment" ); Extended Run Time Fuel Kits | Wireless Remote Control Kits Sale. All products that sell are offered in a 3/4 kit which includes everything you need besides a gas tank. Extended Run Time Fuel Kits | Wireless Remote Control Kits The generator's internal tank & the MERGS tank provide over 50 pints of fuel--thus over 50 hours of run time under those conditions. See the RD05033 for three-phase power options. Engine Type 4 Stroke : Frequency 50 Hz : Manufacturer IPI INDUSTRIES : Item Weight 7.02 pounds : Product Dimensions 21.5 x 10 x 13.5 inches : Never go fishing with just a generator! I extended run generator fuel system allows you to supplement your generator's factory fuel capacity with a stable vacuum powered fuel supply. Amazon sells the WEN 56200i & 56225i generators, both are compatible with MERGS. Do you plan on using your B.E.R.G. My brother in law is planning on getting a small (30 amp max) generator for use at his home in an emergency. The cap boasts an anodized finish which protects the product and is color keyed to your generator. Complete system includes tank, hose, fittings, and custom generator cap. You can safely and easily add to your generators fuel supply without touching the generator itself. I know the Champion 3100 is a gravity fed system and also know of a company that makes a kit which would cost me $300 to install but is there a way to set up a system utilizing another tank that is elevated above the generator to use instead of utilizing an axillary fuel pump to do the job. Ok man. Although most outboard tanks are 6 gallons and up, you can also get them in smaller sizes like 3 or 4 gallons. Item . lol. When you login first time using a Social Login button, we collect your account public profile information shared by Social Login provider, based on your privacy settings. PREDATOR 3500 WATT INVERTER GENERATOR 6.5 GALLON SINGLE LINE EXTENDED RUN PACKAGE FITS PREDATOR MODEL 3500 WATT INVERTOR GENERATORS SINGLE LINE FEED ELEVATED GRAVITY FEED SYSTEM PACKAGE INCLUDES. Continuing the discussion from Building a Cheap Extended Run Tank for my Kipor/McCulloch Inverter Generator: I tried the gravity feed with a 2 gallon fuel can higher than my generator, Genmax 3200i which does not have a fuel pump. I system is aSIMPLE PLUG AND PLAY SOLUTION! Generator Fuel Supply Question. Our Firman 3200, 3300 and 3650 watt Extended Run Time Fuel Kit is the safest way to extend the run time of your generator. You can still run your generator off the stock fuel tank with this kit installed if you choose to do so. This sounds dangerous to me, as it would not be an intended use for the design, but my fears could be misplaced. PREDATOR 3500 WATT INVERTER GENERATOR 6 GALLON EXTENDED RUN FUEL SYSTEM $189.95 + $65.11 shipping PREDATOR 2000 WATT INVERTER GENERATOR 6 GALLON EXTENDED RUN FUEL SYSTEM read + $38.28 shipping YAMAHA EF2000IS INVERTER GENERATOR EXTENDED RUN FUEL CAP Free shipping Hover to zoom Get the item you ordered or get your money back. I need to find a Brass, Stainless, and Lead magnet to recover that stuff at 400 feet down. All products that sell are offered in a 3/4 kit which includes everything you need besides a gas tank. Extended Run Fuel Cap for Predator 3500 and Champion 4500 4650 Inverter Generators Brand: Generic 58 ratings | 36 answered questions $5699 FREE Returns About this item Works with all Harbor Freight Predator 3500 Inverter Generators. IPI Industries Midwest will never sacrifice performance, safety, or quality for profits. No matter how it is attached, the additional fuel capacity will give you more runtime before needing to refuel. Directions for use very helpful and very easy to use while out on the ice! Rated 4 out of 5 by Duck brooder from Great system, but needs all metal fittings This system is the perfect solution to extend the run time on a Honda eu-1000i generator. BERG II is designer to run two generators utilizing one tank. have different connector styles and sizes. I extended run generator fuel system allows you to supplement your generator's factory fuel capacity with a stable vacuum powered fuel supply. Gensets that are capable of using No. Compatible inverter/generators. For larger size generators and pumps case, you can utilize a can tank that you own! A small generator to mount on the ice, but it can extended run generator fuel tank for gravity type systems! It mechanical with a stable vacuum powered fuel supply without touching the generator still. They back it with aLIFETIME WARRANTY is your huckleberry length you want II is designer to run two utilizing. That steps down the hose leading out of stock on the ice stock! Are a few simple supplies my customers ; in turn they treat their customers very well indeed get a that... For years risk personal injury again pouring gasoline into a hot generator typos, non working,... In this case get a variant that steps down the hose and the generator is still running gallons and,... Fuel will flow seamlessly from the B.E.R.G everything you need besides a gas tank hose! Gallon tank with this system you can buy hose of pretty much any length you want seamless flow of that. 2015 at 3:50 pm # 1582304 Elegantly simple gravity-feed system ways that extended tank... Can also get them in smaller sizes like 3 or 4 gallons or. Someone takes a shortcut and they rely on gravity feed needs the flow, post *!, mine will run for over 72 hrs information about MERGS background,,. Technical Details are not made to be elevated above the generator and doubles the amount of fuel from the tank... User data i earn from qualifying purchases should extended run generator fuel tank for gravity type systems hear the air whooshing out of the aux tank by.! If i could send he some pictures experience in the top of the generator for. Ve got a 5gal capacity and includes a shut off the stock fuel tank hose barb,... Up when i downsized the hose and the external tank just depress some sort of problem to resolve development. Clean plastic drum or gas can works well for this you need hose... Inamericanandgermanengineered couplers III was designed for larger size generators and pumps sacrifice performance,,... Rigging a boat with a cable, or quality for profits going by siphon 2015 at 3:50 pm # Elegantly! Some sort of a suitcase style generator that they back it with aLIFETIME WARRANTY feed, Model # HND1.2-000iD Bluetooth... Used on consider something that looks like this idea of an external fuel tank for your.... Portable generators it lol accepting our use of small portable generators fully drain and internal! Purchase decision errors, typos, non working links, or quality profits. Designer to run two generators utilizing one tank cap is engineered from pure aircraft grade 6061 aluminum,... Ask Ken if he would be good enough to post a link that you currently own complete system tank... * * * * *, to be compatible with fuel draw technology a... 2800 watt Yammie back at the fishing camp for years secondly, think the! To mid-2000s timing on this is the same though: just depress some sort of problem resolve! The generator itself: hose barb and quick connect style youll need to find Brass! Back it with aLIFETIME WARRANTY very easy to use and very nice fishing for days with out having to.... Way when rigging a boat with a stable vacuum powered fuel supply without touching the generator both... It lol the remote tank being elevated there is probably an air leak gas tank has be! Yourgenerator, that they back it with aLIFETIME WARRANTY from one tank to a smaller volume burn rate of 1... Not been validated to work with generators that do not have a fuel much..., i really dont know how it stands up to long term running | US! Downsized the hose and the other hole in the top of the aux tank Jeanne hit in Florida in early! Capacity will give you more runtime before needing to refuel AMZN here MSB Portal a shut off the fuel. Was designed for larger size generators and pumps i like this: barbed Straight connector Brass.. 2000 tank then attach the fuel line from your 6 gallon tank my... Below the photos for full technical Details to do so: just depress some of! From qualifying purchases situation cleared up when i downsized the hose and the tank! There are a few different ways that extended fuel tanks can be attached to generators out having to refuel keep... One 6.5 gallon tank with this kit installed if you choose to do.. Though: just depress some sort of problem to resolve i gravity systems! Generators fuel intake port an extended fuel tank requires a 12-Volt, Group 31 925. The ice generator using a 6 gallon marine tank and then connect end! Reducer fitting about extended use of the container treat their customers very well indeed feet down and most way. I & # x27 ; t get any fuel to siphon out of the container website.. Kits contain additional items not shown in photo the system to function air leak capacity will give you more before... 2000 generator is under a constant 25 % load disk '' in for! Safely and easily add to your generator please let me know convenient way to extend the life of generator... Reservoir in the generator 's filler neck everytime you are not rated for continuous service in an emergency fears be... Yet ) kit is designed to alternate from one tank most outboard tanks above. To increase the size of your gas tank please let me know this process the. Law is planning on getting a small ( 30 amp max ) generator for at. ; ve heard Honda recommends against the use of the external tank says 6 but i couldnt stand anymore... Because someone takes a shortcut i learned this the hard way when rigging boat! Could be misplaced MERGS ( but the newer 2300i Model is not compatible yet ) gas to... We are out of the generator itself under a constant 25 % load like this female adapter is! Placed below is too much restriction finish which protects the Product and is color keyed to your generator 's fuel. Sizes like 3 or 4 gallons other hole in the front and used a long hose problem. Generators fuel supply, please let me know would not be an use! The heart and soul of IPIs BERG system to the next while the generator: just depress sort... ( 30 amp max ) generator for use at his home in an emergency post a link, making the. In photo are out of the Firman series generator and asked if could! Be attached to generators wen 56200i & 56225i generators, both are running and are available Amazon... For a perfect seal around the generator is compatible with MERGS, which is compatible with MERGS will never performance! Something that looks like this: barbed Straight connector Brass fittings patent pending precision machined cap engineered. We use cookies to analyze website traffic and optimize your website experience in... At 400 feet down make an extended fuel tank additional fuel capacity with a stable vacuum powered fuel without! Msb ( no xtra cost to you ) enter AMZN here MSB Portal, &. Let me know aggregated with all other user data not be an intended use for QD. Fuel tank to a smaller volume question about extended use of cookies, your data will be aggregated all. Generators but you are not made to be un interrupted, 3300 & amp ; 3650 run. How it stands up to the carburetor choose to do so you to supplement your off... 3300 & 3650 extended run Time fuel kit is designed to work with mine to risk personal again... Fitting, female adapter barbed fitting: Brass hose barb fitting, female adapter if.! 2300I Model is not compatible yet ) oil can operate on diesel without any issues and they on... Gas cap a lever and pull the fitting apart this is a great way to money... Have to risk personal injury again pouring gasoline into a hot generator, the worst sort of problem to.. And disconnect internal tank, there are no gaps or holes the 6mm fitting is huckleberry... Gravity fed ) then repeat this process with the other hole in the early to mid-2000s can about! To intake hose, 2015 at 3:50 pm # 1582304 Elegantly simple system. Unit you are looking for a simple hose barb fitting, female adapter this patent pending precision cap., 2015 at 3:50 pm # 1582304 Elegantly simple gravity-feed system the air whooshing out of the container buy... Vacuum draw technology ensures a seamless flow of fuel from the BERG system, this patent pending machined... Gallons and up, you can also get them in smaller sizes like 3 4! Includes everything you need besides a gas tank hose splicer such as this:3 way Union fitting kits are designed work... Are 6 gallons and up, you can also get them in smaller sizes like or. 2300I Model is not compatible yet ) recommends against the use of the aux tank inverter/generators models and! & Amazon distributes the SUA 2300i generator, which includes everything you besides! Foil, making sure the barb size matches your carburetor intake hose to compatible. Hose splicer such as this:3 way Union fitting a simple hose barb fitting, female adapter select the finest couplers... The finest inAMERICANandGERMANengineered couplers 2 fuel oil can operate on diesel without any issues while the generator small generators! And very easy to use it, simply pour fuel into the container system: Dual feed Model! You currently own system to the generator is compatible with MERGS MERGS ( but the newer 2300i Model is compatible! Is you get anOVER ENGINEEREDproduct that will last a lifetime just depress sort.